Shop Now
-
Hydraulics
- Parts
- Fittings
- Motors
- Filters
- Hose Tails
-
Adaptors
- Tube Weld
- Caps
-
Straight
-
Nipple
- BSPP Male x BSPP Male
- BSPP Male x JIC Male
- BSPT Male x BSPT Male
- BSPT Male x JIC Male
- BSPT Male x UNO Male
- JIC Male x JIC Male
- NPT Male x NPT Male
- ORFS Male x Metric Stud Male
- ORFS Female x ORFS Male
- NPT Male x NPT Female
- BSPT Male x MS Male
- BSPP Male x UNO Male
- BSPT Male x BSPP Male
- BSPT Male x NPT Male
- NPT Male x JIC Male
- JIC Male x ORFS Female
- JIC Male x UNO Male
- JIC Male x ORFS Male
- JIC Male x Metric Stud Male
- UNO Male x ORFS Male
- ORFS Male x ORFS Male
- JIC Male x JIC Female
- BSPP Female x JIC Male
- BSPT Male x ORFS Male
- BSPT Male x ORFS Female
- Metric Stud Male x Metric L Ma
- ORFS Male x ORFS Fixed Female
- JIC Male x Code 62
- Metric L Male x Metric L Male
- Reducing Bush
- Socket
- Bulkhead
- BSPT Male Suction Tail
- UNO Male Suction Tail
-
Male x Female Swivel
- BSPP Male x BSPP Female
- BSPP Male x JIC Female
- BSPP Male x ORFS Male
- BSPT Male x BSPP Female
- JIC Female x ORFS Male
- BSPP Female x UNO Male
- JIC Female x UNO Male
- BSPT Male x JIC Female
- ORFS Fixed Female x ORFS Male
- JIC Male x JIC Female Restr
- BSPP Male x ORFS Female
- JIC Male x BSPP Female
- JIC Male x JIC Female
- BSPP Male x Metric H Female
- BSPT Female x BSPP Male
- BSPP Male x Metric L Male
- BSPP Male x Metric L Female
- BSPP Male x Metric H Male
- BSPT Female x BSPT Male
- OEM Female x BSPP Male
- Male x Female Solid
-
Nipple
- Plug
- Tee Piece
- Cross
- Flange Clamps
- Banjo Bolts
- Tube Fittings
- 45 Degree Elbow
-
90 Degree Elbow
-
Elbow Block
- BSPP Male x JIC Male
- BSPT Male x JIC Male
- BSPP Male x ORFS Male
- BSPT Male x BSPP Female
- Metric L Male x Metric L Femal
- NPT Male x NPT Female
- JIC Male x Metric Male
- BSPP Female x UNO Male
- JIC Male x UNO Male
- BSPT Female x BSPT Female
- BSPP Male x BSPP Female
- BSPP Male x BSPP Male
- BSPT Male x BSPT Female
- BSPT Male x BSPP Male
- BSPT Male x UNO Male
- BSPT Male x BSPT Male
- BSPT Male x Suction tail
- NPT Male x JIC Male
- JIC Male x JIC Female
- JIC Male x ORFS Female
- JIC Male x JIC Male
- UNO Male x ORFS Male
- UNO Male x Suction Tail
- ORFS Male x ORFS Male
- NPT Male x ORFS Female
- ORFS Female x ORFS Male
- Elbow Tube
- Bulkhead
-
Elbow Block
- Hose
- Valves
- Pumps
- Cylinders
- Power packs
- Breakaway Couplings
- Pipe Clamps
- Seals
- Ferrules
- Equipment
- Hydraulic Hose Kits
- Misc
What do flow control valves do?
What do flow control valves do?
In a hydraulic system, flow control is used to manage speed. All the devices mentioned here control the speed of an actuator by regulating the flow rate. Flow rate also determines the rate of energy transfer at any given pressure. The actuator force multiplied by the distance through which it moves (stroke) equals the work done on the load. The energy transferred must also equal the work done. Actuator speed determines the rate of energy transfer (power), and speed is thus a function of flow rate.
Eight different types of flow-control valves are commonly used in hydraulic systems.
Orifices—A simple orifice in a hydraulic line is the most rudimentary method for controlling flow and can also be used as a pressure-control device. When used to control flow, the orifice is placed in series with the pump. An orifice can be a drilled hole in a fitting, in which case it is fixed; or it may be a calibrated needle valve, in which case it functions as a variable orifice, both types are non-compensated flow-control devices.
Flow regulators: These devices, are slightly more sophisticated than a fixed orifice and consist of an orifice that senses flow rate as a pressure drop across the orifice. A compensating piston adjusts to variations of inlet and outlet pressures. This compensating ability provides closer control of the flow rate under varying pressure conditions.
Bypass flow regulators: In this flow regulator, flow in excess of the set flow rate returns to the reservoir through a bypass port. Flow rate is controlled fluid passing across a variable orifice regulated by the compensator piston. The bypass flow regulator is more efficient than a standard flow regulator.
Demand-compensated flow controls: Flow controls can also bypass excess system flow to a secondary circuit. Fluid is routed at a controlled flow rate to the primary circuit, and bypass fluid can be used for work functions in secondary circuits without affecting the primary one. There must be flow to the primary circuit for this type of valve to function—if the primary circuit is blocked, the valve will cut off flow to the secondary circuit.
Pressure-compensated, variable flow valves: This flow control is equipped with an adjustable variable orifice placed in series with a compensator. The compensator automatically adjusts to varying inlet and load pressures, maintaining a constant flow rate under these operating conditions to accuracies of 3% to 5%, Pressure-compensated, variable flow-control valves are available with integral reverse-flow check valves (which give fluid unrestricted flow in the opposite direction) and integral overload relief valves (which route fluid to tank when a maximum pressure is exceeded).
Pressure- and temperature-compensated, variable flow valves: The viscosity of hydraulic oil varies with temperature (as do the clearances between a valve’s moving parts), output of a flow-control valve may tend to drift with temperature changes. To offset the effects of such temperature variations, temperature compensators adjust the control orifice openings to correct the effects of viscosity changes caused by temperature fluctuations of the fluid.
Priority valves: A priority valve is a flow-control valve that supplies fluid at a set flow rate to the primary circuit, thus functioning as a pressure-compensated flow-control valve. Flow in excess of that required by the primary circuit bypasses to a secondary circuit at a pressure somewhat below that of the primary circuit. Should inlet or load pressure (or both) vary, the primary circuit has priority over the secondary — as far as supplying the design flow rate is concerned.